System interview
Brightwater Business Network
- Organization
- Brightwater Fasteners Inc. (fictional)
- Framework
- NIST SP 800-171 Rev. 2 — Protecting Controlled Unclassified Information in Nonfederal Systems and Organizations
- Exported
- 2026-11-22
- Answered
- 81 of 81 questions
- This file holds
- Interview only
1. System identification
| Question | Answer |
|---|---|
| System name | Brightwater Business Network |
| Organization name | Brightwater Fasteners Inc. (fictional) |
| System owner (name and title) | Dana Whitlock, President |
| Security officer / ISSO (name and title) | Luis Ferreira, Office and IT Manager |
| Describe the system | Brightwater Fasteners is a 14-person shop in Erie, Pennsylvania that machines specialty bolts and fittings for two DoD prime contractors. The Brightwater Business Network is the office network, the Microsoft 365 Business Premium tenant and the six office laptops used to receive purchase orders, delivery schedules and part specifications from those primes. The information is Federal Contract Information (FCI). It arrives by email and through the primes' supplier portals, is saved in SharePoint Online and printed for the shop floor. No CUI is received; the primes have confirmed that drawings sent to Brightwater are not marked CUI. The shop-floor CNC machines are on a separate network and do not handle FCI. |
| What kinds of CUI does the system handle? | None - Federal Contract Information (FCI) only |
| Why is the SSP needed? | CMMC Level 1; Prime contractor / customer flow-down |
| Operational status | Operational |
2. Boundary and environment
| Question | Answer |
|---|---|
| Where is CUI stored, processed or transmitted? | Cloud SaaS (e.g. Microsoft 365); Company laptops / desktops; Paper / hard copy |
| Cloud platforms in scope | Microsoft 365 Commercial |
| How many people use the system? | 11-50 |
| Types of users | Employees; Privileged administrators |
| Physical locations in scope | One building in Erie, PA: front office and shop floor |
| Do users access the system remotely? | Only occasionally |
| Describe the network and system boundary | A small business firewall separates the office network from the internet. The office VLAN holds the six laptops and a printer. The shop-floor VLAN holds the CNC machines and has no route to the office VLAN. Guest Wi-Fi is on its own VLAN with internet access only. |
| Connections to external systems | Prime contractor supplier portals, used through a web browser. No system-to-system connections. |
| External service providers | Lakeshore IT Services (fictional), a local MSP, maintains the firewall and laptops under a monthly contract. |
3. Identity and access
| Question | Answer |
|---|---|
| Identity provider / directory | Microsoft Entra ID |
| Multi-factor authentication coverage | All users, all access |
| MFA methods in use | Authenticator app |
| How is privileged (admin) access handled? | The office manager and the MSP each have one separate admin account. Daily work uses standard accounts. |
| How are accounts requested, approved, reviewed and removed? | The president approves new accounts by email; the office manager creates them. Accounts are removed on the last day of employment. Accounts are reviewed once a year. |
| Remote access methods | Direct to cloud services only |
| Wireless access to the system | Yes, WPA2/WPA3-Enterprise (802.1X) |
| Mobile device management | Microsoft Intune |
| Session lock, logout and lockout settings | Laptops lock after 15 minutes; Entra ID smart lockout defaults |
4. Endpoints and infrastructure
| Question | Answer |
|---|---|
| Endpoint operating systems | Windows 11 |
| Server platforms | No servers (SaaS only) |
| Endpoint protection / EDR | Microsoft Defender for Endpoint |
| Firewalls and boundary protection | Small business firewall with default-deny inbound, managed by the MSP. Web filtering blocks known malicious sites. The shop-floor and guest networks cannot reach the office network. |
| Is the CUI environment segmented from the rest of the network? | Partially (VLANs / firewall rules) |
| Encryption at rest | BitLocker; Cloud provider encryption |
| Encryption in transit | TLS 1.2 or later |
| Is cryptography protecting CUI FIPS-validated? | Unknown |
| Email and collaboration platform | Exchange Online and SharePoint Online in Microsoft 365 Business Premium |
| Configuration baselines and enforcement | Intune / MDM configuration profiles |
| How are changes to the system requested, reviewed and approved? | Changes are requested from the MSP by email and approved by the president. |
| How is the hardware and software inventory maintained? | The MSP keeps a spreadsheet of laptops, the firewall and software licences, updated when equipment changes |
| Patch management tool and timelines | Windows Update for Business through Intune; firewall firmware updated quarterly by the MSP |
| Vulnerability scanning tool and frequency | None scheduled |
| Backups | Microsoft 365 data backed up nightly by the MSP's cloud backup service |
5. Monitoring and response
| Question | Answer |
|---|---|
| Log collection / SIEM | Local logs only |
| Who reviews logs and alerts, and how often? | The MSP reviews Defender alerts as they arrive |
| Audit log retention period | Microsoft 365 defaults (90 days) |
| Time synchronization source | Windows time synchronizes with Microsoft time servers |
| Incident response capability | Handled by MSSP / outsourced |
| How and how often is incident response tested? | Not tested |
| How are incidents reported externally? | The president notifies the affected prime contractor by phone and email |
| Who performs system maintenance? | Lakeshore IT Services maintains all office equipment, on site or by remote support sessions the office manager starts. |
6. Physical, media and personnel
| Question | Answer |
|---|---|
| Physical access controls | Locks and key control; Visitor log and escort; Alarm system |
| Safeguards at alternate work sites (home offices) | Laptops taken home use the same Intune settings; FCI is not printed at home |
| Media protection practices | Removable media prohibited; Media sanitized per NIST SP 800-88; Paper CUI shredded |
| Personnel screening before access to CUI | Non-disclosure agreement |
| Termination and transfer process | Documented checklist, access removed same day |
| Security awareness training | Annual 30-minute online training for office staff |
| Role-based training for administrators and security staff | None |
7. Policies and governance
| Question | Answer |
|---|---|
| Status of policies, plans and procedures | |
| Access control policy | Documented and approved |
| Awareness and training policy | Informal practice only |
| Audit and accountability policy | None |
| Configuration management policy / plan | Informal practice only |
| Identification and authentication policy | Documented and approved |
| Incident response plan | Documented and approved |
| Maintenance policy | Informal practice only |
| Media protection policy | Documented and approved |
| Personnel security policy | Informal practice only |
| Physical protection policy | Documented and approved |
| Risk assessment policy | None |
| Security assessment and monitoring policy | None |
| System and communications protection policy | Documented and approved |
| System and information integrity policy | Documented and approved |
| Security planning policy | None |
| System and services acquisition policy | None |
| Supply chain risk management plan | None |
| Rules of behavior / acceptable use | Documented and approved |
| Plan of action and milestones (POA&M) process | None |
| How often are policies reviewed and updated? | Once a year when the CMMC Level 1 self-assessment is done |
| Organization-defined parameters (ODPs) | Not defined yet |
| Risk assessments | None performed |
| Security control assessments | Annual CMMC Level 1 self-assessment, first one due this year |
| Supplier and acquisition security | Equipment is bought from mainstream retailers through the MSP. |
| Anything else an assessor should know? | Brightwater handles FCI only. If a prime sends CUI, it is returned and the prime is told, because Brightwater has no CMMC Level 2 environment. |
8. Follow-up questions
| Question | Answer |
|---|---|
| Who decides that a document from a prime is FCI and not CUI? | The office manager checks every incoming drawing for CUI markings; anything marked CUI is not saved and is returned to the sender. |
| How are visitors to the shop floor recorded? | Visitors sign the paper log at the front desk and are escorted by an employee at all times. |